| Element | Standard | Min | Notes |
| Single door width | 900 mm | 800 mm | Standard entry door |
| Double door width | 1,800 mm | 1,500 mm | Double door |
| Door height | 2,100 mm | 2,000 mm | Standard door height |
| Wheelchair accessible | 900 mm | 900 mm | Wheelchair accessible minimum |
| Fire door (single) | 900 mm | 900 mm | Emergency exit minimum width |
| Door handle height | 900~1,100 mm | 800 mm | Floor to handle |
| Element | Standard | Min | Notes |
| Residential corridor | 1,200 mm | 1,000 mm | Residential corridor |
| Public corridor | 1,800 mm | 1,500 mm | Public facility corridor |
| Hospital corridor | 2,400 mm | 1,800 mm | Considers bed transport |
| Two-way wheelchair | 1,800 mm | 1,500 mm | Wheelchair two-way passing |
| One-way wheelchair | 1,200 mm | 900 mm | Wheelchair one-way |
| Ceiling height | 2,400 mm | 2,100 mm | Corridor ceiling height |
| Element | Standard | Min | Notes |
| Stair width (residential) | 1,200 mm | 900 mm | Residential stair |
| Stair width (public) | 1,500 mm | 1,200 mm | Public facility |
| Handrail height | 900 mm | 850 mm | Floor to top of handrail |
| Headroom | 2,200 mm | 2,100 mm | Headroom above stairs |
| Landing depth | 1,200 mm | Equal to stair width | Landing depth |
| Element | Standard | Min | Notes |
| Toilet room width | 1,000 mm | 900 mm | Toilet stall width |
| Toilet room depth | 1,500 mm | 1,200 mm | Toilet stall depth |
| Accessible toilet | 1,600×2,000 | 1,400×1,800 | Accessible toilet |
| Lavatory height | 800 mm | 750 mm | Top of lavatory |
| Shower size | 900×900 | 800×800 | Shower booth |
| Mirror bottom | 1,000 mm | 900 mm | Floor to bottom of mirror |
| Element | Standard | Min | Notes |
| Counter height | 850 mm | 800 mm | Counter height |
| Counter depth | 600 mm | 550 mm | Counter depth |
| Upper cabinet bottom | 1,400 mm | 1,350 mm | Upper cabinet bottom height |
| Work triangle max | 6,000 mm | - | Fridge-sink-range total |
| Passage width | 1,200 mm | 900 mm | Kitchen passage |
| Two-cook passage | 1,500 mm | 1,200 mm | Two-cook passage |
| Element | Standard | Min | Notes |
| Single bed | 1,000×2,000 | 900×1,900 | Single bed |
| Double bed | 1,400×2,000 | 1,350×1,900 | Double bed |
| Queen bed | 1,500×2,000 | - | Queen bed |
| King bed | 1,800×2,000 | - | King bed |
| Bedside clearance | 600 mm | 450 mm | Bedside clearance |
| Closet depth | 600 mm | 550 mm | Closet depth |
| Min bedroom size | 9 m² | 6.5 m² | Min bedroom area (KR) |
| Element | Standard | Min | Notes |
| Standard parking | 2,500×5,000 | 2,300×5,000 | Standard parking (KR) |
| Compact parking | 2,300×4,500 | 2,000×4,500 | Compact parking |
| Accessible parking | 3,300×5,000 | 3,300×5,000 | Accessible parking |
| One-way aisle | 5,000 mm | 3,500 mm | One-way aisle |
| Two-way aisle | 6,000 mm | 5,500 mm | Two-way aisle |
| Ceiling height | 2,700 mm | 2,300 mm | Underground parking clearance |
| Element | Standard | Min | Notes |
| Wheelchair turning | 1,500×1,500 | 1,400×1,400 | Wheelchair turning space |
| Ramp slope | 1:15 | 1:12 | Ramp slope |
| Ramp width | 1,500 mm | 1,200 mm | Ramp clear width |
| Elevator min | 1,600×1,350 | 1,100×1,350 | Accessible elevator |
| Switch height | 1,000 mm | 800 mm | Switch/outlet height |
| Counter max height | 850 mm | - | Accessible counter |